I have the chiller you want

definition:
Air-cooled chiller is a type of chiller, because the unit's own cooling method is fan exhaust cooling, which is called air-cooled chiller.
The main four components of air-cooled chiller are: compressor; fin condenser; shut-off valve; evaporator.
Refrigeration principle:
Compression compressors provide circulating pressure for the refrigerant (Freon) in the refrigeration system; the compressed refrigerant becomes high-temperature and high-pressure gas, which is cooled by the natural air drawn by the fan when it is condensed by fins, and becomes medium-temperature and high-pressure gas; After passing through the small diameter of the shut-off valve, the high-pressure refrigerant enters the evaporator and rapidly expands and absorbs a large amount of heat when vaporized into gas. After the temperature of the evaporator becomes low, it exchanges heat with cooling water to achieve the cooling effect. The compressor sucks in again to compress and circulate. So as to achieve the purpose of circulating refrigeration.

Air-cooled cold water features:
1. The unit selects a large brand fully-enclosed scroll compressor for stable operation and long service life.
2. Equipped with multiple protection devices, simple operation and convenient maintenance.
3. The air-cooled chiller can use a single or multiple compressor combinations, and the power can be customized according to the load power. The function can also be automatically adjusted during operation to maximize energy savings.
4. Chassis The shell of the chassis adopts electrostatic spray anti-rust treatment, with beautiful appearance and reasonable structure.
5. You can choose whether to install a built-in water storage tank and a circulating water pump according to the actual cooling process.
Supporting industries:
Air-cooled chiller is a standard or non-standard auxiliary machine, which can be widely used in: rubber and plastic industry, auto parts and production and testing, machining machinery, biochemical reactors, electronics industry, food processing storage, etc. Temperature control during R & D, manufacturing and storage.

Parameter table 1:
parameter model SJ-1 / 2AS SJ-01AS SJ-02AS SJ-03AS SJ-04AS SJ-05AS SJ-06AS SJ-08AD
Cooling capacity KW 1.53 2.94 5.67 8.86 10.9 14.5 17.2 21.8
Kcal / h 1316 2528 4872 7620 9374 12470 14792 18748
input power KW 0.68 1.31 2.6 3.45 4.22 4.97 5.47 8.6
power supply 1N ~ 220V 50HZ 3N ~ 380V 50HZ
Refrigerant name R22
Filling amount / KG 0.6 0.8 1.6 2 2.4 3.3 3.9 2.4 * 2
Controller Capillary
compressor Types of Fully enclosed swing Hermetic scroll or piston
Power KW 0.55 0.75 1.5 3.07 3 4.22 4.68 3 * 2
Cooling air volume M³ / h 800 1000 2000 3000 4000 5000 6000 8000
frozen water Water volume (M³ / h) 0.26 0.51 0.97 1.53 1.87 2.4 2.91 3.75
Water tank / M³ 0.022 0.028 0.038 0.06 0.06 0.07 0.11 0.11
Pipe diameter G1 / 2 " G1 / 2 " G3 / 4 " G3 / 4 " G3 / 4 " G1 G1 G1-1 / 2 "
Water pump Power / KW 0.375 0.375 0.375 0.375 0.375 0.75 0.75 0.75
Pressure / Kpa 180 180 250 242 242 290 290 290
Dimensions Length / MM 600 600 820 945 945 1035 1200 1470
Width / MM 400 400 460 550 550 610 650 710
High / MM 940 940 1170 1370 1370 1385 1480 1700
weight KG 45 60 100 130 160 190 220 270


Parameter table 2:

parameter model SJ-10AD SJ-12AD SJ-15AD SJ-20AD SJ-25AD SJ-30AT SJ-40AF SJ-50AF SJ-60AF
Cooling capacity KW 29 34.4 44.5 60 76 90 120 152 180
Kcal / h 24940 29584 38270 51600 65360 77400 103200 130720 154800
input power KW 11 12 15.5 20 22.1 31.75 39.35 48.7 60.7
power supply 3N ~ 380V 50HZ / 60HZ
Refrigerant name R22
Filling amount / KG 6 8 9 12 16 20 25 32 40
Control Method Capillary External balance force thermal expansion valve
compressor Types of Fully closed spin or piston
Power KW 4.22 * 2 4.68 * 2 8.2 + 4.22 8.1 * 2 9.15 * 2 8.1 * 3 8.1 * 4 9.15 * 4 8.186
Cooling air volume M³ / h 10000 12000 15000 20000 25000 30000 40000 48000 66000
frozen water Water volume (m3 / h) 4.82 5.81 7.6 10.16 12.34 15 19.53 23.3 30.52
Water tank / m3
0.188 0.188 0.285 0.285 0.405 0.405 0.61 0.61 0.7
Pipe diameter G2 " G2 " G2 " G2 " G2-1 / 2 " G2-1 / 2 " G3 " G3 " G3-1 / 2 "
Water pump Power / KW 1.5 1.5 1.5 2.2 2.2 4 4 4 4
Pressure / Kpa 205 205 205 220 220 250 250 250 250
Dimensions Length / MM 1470 1600 1680 1955 2080 2400 2250 2700 3400
Width / MM 710 800 890 940 1000 1100 1550 1620 1800
High / MM 1435 1600 1600 1600 1800 1800 1820 1850 1850
weight KG 350 370 520 590 790 880 1100 1280 1420

-10℃风冷式冷水机
-10 ℃ air-cooled chiller
60KW风冷式冷水机
60KW air-cooled chiller
低温型风冷式冷水机
Low-temperature air-cooled chiller
工业风冷式冷水机
Industrial air-cooled chiller
辊轮风冷式冷水机
Roller air-cooled chiller
恒温冷热一体机
Constant temperature hot and cold machine
实验室风冷式冷水机
Laboratory air-cooled chiller
箱体式风冷式冷水机
Box type air-cooled chiller
小型风冷式冷水机
Small air-cooled chiller
七乐彩 龙博线上娱乐 欢乐拼三张 欢乐拼三张
15062688501